PDU sockets, Power Distribution Unit sockets China manufacturer
(general the PDU are viewed as RPDU:RACK- POWER DISTRIBUTION UNIT)
As the manufacturer/exporter of low & medicum voltage electric
equipment, we have developed the new series of PDU sockets and socket modulars, which is one of power distribution products for the usage of
distribution unit, power protection, electrical distribution
systems, power distribution box,power distribution unit,power
distribution solutions.
We have the strong mould design and production ability to support
the material of the our Industrial plugs & sockets, Power
Distribution Unit Sockets--PDF Sockets,and other kinds
series,like:Desk Sockets, Floor Sockets/Ground Sockets,Ceiling
Sockets.
Large industrial units are used for taking high voltage and
amperage and reducing it to more common and useful levels, for
example from 220V 30A single phase to multiple 110V 15A or 110V 20A
plugs. They are used incomputer data centers, stage shows, by DJs,
and in other electrically intensive applications. Some have
features like remote monitoring or control down to the individual plug.
A 240 volt circuit (120 volts x2 plus neutral and ground) has two
legs at 120 volts. A distro switches and provides circuit
protection for the taps off of the phases/legs. A PDU allows for a
solidly bonded neutral, and a safe grounding system.
PDU also refers to what amounts to a well-constructed power strip
suitable for datacenter use. Two basic varieties distinguished by
the type of input power are common: single-phase and three-phase.
The output power (i.e. the power to the load device) is always
single-phase, however. In the case of a three-phase PDU, each of
the three phases appears individually on every third receptacle.
PDUs can be dumb -- meaning that they have no instrumentation and
are not manageable, or they can be metered -- meaning that they are
equipped with a display that shows current load on each phase, or
they can be switched -- meaning that some or all of their
receptacles can be individually switched on or off remotely.
One of the challenges in selecting PDUs for a datacenter
application is to balance the relatively high cost of a switched
PDU versus the relatively low cost of a dumb PDU, but then managing
the risk that the phases may become unbalanced, or devices may be
unexpectedly plugged in, possibly tripping a circuit breaker.
(1) Types for Different Countries:France Type PDU, UK Type PDU,
Italy Type PDU, US Type PUD Socket, IEC Type PDU sockets,
Omnipotence Type, National Standard Type PDU socket...
(2) Installation Direction: vertical 19" mountable units /
horizontal 19" mountable power distribution units;
(3) ll functional modules are adopted PC/ABS alloy ,hot change
temperature reach to above 120„ƒ ,fire-retardant haracteristic
accords with UL94-V0 standard.
(4) Certifications for our PDU Sockets Supplier : GSCEUL3C;
----------------------------------------------------
Model: PB2L-06S
Socket/Outlet Standard : BS1363
Outlet QTY: 6 way
Power Input Style : Left end single input style
Brackets Installation Style: Frontal installation style
Cable plug : BS1363
Control functions : Switch
Protection functions: No
Shell colour & Material: Black; Aluminium modular design:
Cable specification: 3*1.5mm2*3M; Standard 3 metre power cord:
Electrical Rating: 13A 250VAC
Maximum load current: 13A
Maximum load capacity : 4KW
Size of this UK PDU socket: L*W*H: 482.6*44.4*62mm
Relative humidity for PDU: 10-90%
UK power distribution units are the standard choice in sever and networking 19 racks
connecting directly to the targeted equipment, they are available
as 13A to UK power or C19 plug. All PDU products of Betterbell are modularized,customer can
choose the relative modules and power input cables.
All functional modules are adopted PC/ABS alloy ,hot change
temperature reach to above 120„ƒ ,fire-retardant characteristic
accords with UL94-V0 standard.
----------------------------------------------------
See more products from this supplier.